Chapter 8 Troubleshooting
Multi-Tech Systems, Inc. MT5600BA-V92 User Guide 43
Try entering the &V1 command to display information about the last connection, making a LCD print
of the connection statistics, and checking for parameters that might be unacceptable.
Modem Doesn’t Work with Caller ID
Caller ID information is transmitted between the first and second rings, so if autoanswer is turned
off (S0=0) or if the modem is set to answer after only one ring (S0=1), the modem will not receive
Caller ID information. Check your initialization string, and if necessary change it to set the modem to
answer after the second ring (S0=2).
Make sure that you have Caller ID service from your telephone company.