Chapter 10 – Internet Service Commands
Multi-Tech Systems, Inc. AT Commands for EDGE Modems (S000371B) 124
<conParmValue-alphabet>
Character set selectable with <conParmValue> for <conParmTag> value “alphabet”.
“0“ Character set determined with AT+CSCS applies. Default.
“1“ International Reference Alphabet (IRA, seven bit ASCII) applies.
<conParmValue-dataRate>
Supported data rate values in <conParmValue> for <conParmTag> value “dataRate”.
“0“ 14.4 KBaud
“1“ 9.6 KBaud. Default.
<conParmValue-dataType>
Supported data call type values in <conParmValue> for <conParmTag> value “dataType”.
“0“ ISDN
“1“ Analog. Default,
<conParmValue-authMode>
Supported authentication mode values in <conParmValue> for <conParmTag> value “authMode”.
“none“
“PAP“ (Default)
“CHAP“
“MsChapV1“
10.1.1 Example: Default Values of a CSD Connection Profile
As stated earlier, the “conType” selected with AT^SICS determines all other matching profile parameters related
to this “conType”. Once “conType” is set in a new profile, the default values of all other related parameters are
assumed. To view the default settings you can use the read command AT^SICS?
at^sics=1,conType,CSD Select connection type CSD, identified by <con-ProfileId>1
OK
at^sics? Query current profiles.
^SICS: 0, “conType”, “” Profile with <conProfileId> 0 is still empty.
^SICS: 1, “conType”, “CSD” The new CSD profile just created is indicated with all
related parameters set to their default.
^SICS: 1, “alphabet”, “0” Character set determined with AT+CSCS applies when
string parameters are input with AT^SICS.
^SICS: 1, “user”, “” No user name set.
^SICS: 1, “passwd”, “” No password set.
^SICS: 1, “authMode”, “PAP” Authentication protocol PAP is assumed as default.
^SICS: 1, “inactTO”, “0” No inactivity timeout set.
^SICS: 1, “calledNum”, “” No destination set.
^SICS: 1, “dataRate”, “1” Data rate set to 9.6 kbaud.
^SICS: 1, “dataType”, “1” Remote device is analog, e.g. an analog modem.
^SICS: 2, “conType”, “” Profile with <conProfileId> 2 is still empty.
^SICS: 3, “conType”, “” Profile with <conProfileId> 3 is still empty.
^SICS: 4, “conType”, “” Profile with <conProfileId> 4 is still empty.
^SICS: 5, “conType”, “” Profile with <conProfileId> 5 is still empty.
OK
10.1.2 Example: GPRS Connection Profile
at^sics=0,conType,GPRS0 Select connection type GPRS0.
OK
AT^SICS=0,inactTO,”0” Inactivitiy timeout = 0 (default).
OK
AT^SICS=0,dns1,”193.254.160.1” IP address of Primary DNS server.
OK
AT^SICS=0,authMode,”PAP” Authentication protocol PAP (default).
OK
AT^SICS=0,passwd,t-d1 GPRS services password provided by the German operator
T-D1.
OK
AT^SICS=0,apn,”internet.t-d1.de” APN to access the GPRS services provided by the German
operator T-D1.
OK
Vue de la page 123
1 2 ... 119 120 121 122 123 124 125 126 127 128 129 ... 252 253

Commentaires sur ces manuels

Pas de commentaire

MaxxAir BF24TFORGPRO Handbücher

Bedienungsanleitungen und Benutzerhandbücher für Nein MaxxAir BF24TFORGPRO.
Wir stellen 1 PDF-Handbücher MaxxAir BF24TFORGPRO zum kostenlosen herunterladen nach Dokumenttypen zur Verfügung Gebrauchs- und Pflegehandbuch


Inhaltsverzeichnis





Weitere Produkte und Handbücher für Nein MaxxAir

Modelle Dokumententyp
HVFF 20S REDUPS Bedienerhandbuch   MaxxAir HVFF 20S REDUPS Instructions / Assembly, 1 Seiten