MultiVOIP User Guide
If you are connecting the station side of a telephone switch (PBX) to your MultiVOIP, connect
one end of an RJ11 phone cord to the Voice/Fax Channel 1 FXO connector on the back of
the MultiVOIP and the other end to the phone jack.
If you are connecting an E&M trunk from a telephone switch to your MultiVOIP, connect one
end of an RJ45 phone cord to the Voice/Fax Channel 1 E&M connector on the back of the
MultiVOIP and the other end to the trunk. Refer to Appendix B for E&M cabling pinout.
If you are connecting to an E&M trunk, you need ensure that the E&M trunk jumper is in the
correct position for the E&M type trunk. The default E&M jumper position is E&M type 2. To
change the E&M jumper position, perform the E&M jumper block positioning procedure.
7 Repeat the above step to connect the remaining telephone equipment to each Voice/Fax
Channel on your MultiVOIP.
8 Turn on power to the MultiVOIP by placing the ON/OFF switch on the back panel to the ON
position. Wait for the BOOT LED on the MultiVOIP to go OFF before proceeding. This may
take a couple of minutes to go OFF.
9 At this time your VOIP network should be fully operational, dial one of the sites in your
network using the dialing directory supplied by your VOIP Administrator.