E1 Parameter Definitions (cont’d)
Field Name Values Description
Detect Flash
Hook
Y/N This setting determines whether
or not the MultiVOIP responds
to hook-flash signals.
Detection Time 100 – 1500
milliseconds
Minimum hook-flash time that
will be interpreted as a valid
flash by the MultiVOIP.
Generation
Time
100 – 1500
milliseconds
In some systems, a MultiVOIP
might receive a hook-flash
signal from an upstream device
(a PBX, voip or other device)
and must replicate it to a
downstream device. This
parameter determines the
duration of the hook-flash
signal that is passed to a
downstream device.