Multitech MTCBA-C-U-N2 Spécifications Page 119

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 308
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 118
Chapter 8 – Network Service Commands
Multi-Tech Systems, Inc. AT Commands for EDGE (E1) Modems (S000474A) 119
8.6 AT+CSQ Signal Quality
Description: The AT+CSQ execute command indicates the received signal strength <rssi> and the channel bit
error rate <ber>.
Syntax: Test Command: AT+CSQ=?
Response: +CSQ: (list of supported<rssi>s), (list of supported<ber>s)
OK
Exec Command: AT+CSQ
Response: +CSQ: <rssi>,<ber>
OK
Parameter:
<rssi>
0 -113 dBm or less
1 -111 dBm
2..30 -109... -53 dBm
31 -51 dBm or greater
99 not known or not detectable
<ber>
0..7 as RXQUAL values in the table in GSM 05.08 section 8.2.4.
99 not known or not detectable
Notes:
After using network related commands such as AT+CCWA, AT+CCFC, AT+CLCK, users are advised to wait 3s
before entering AT+CSQ. This is recommended to be sure that any network access required for the preceding
command has finished.
This command is not PIN protected.
This command is not supported in airplane mode.