Chapter 2 – Command Line Interface (CLI)
Command Line Interface and Application Examples for Multi-Tech Systems, Inc. IP Modules (S000368F) 40
PPP Commands – Setup
Command Syntax set ppp <interface> ping-keepalive <enable/disable>
Description
Enables/disables the ping-keepalive feature.
Default Value
Disabled
Success
OK
Error 1. Too few arguments
Too few arguments. Possible argument(s) are:
ping-host
ping-interval
ping-no-of-packets
Possible value(s) are enable or disable.
2. Invalid String
Invalid argument "invalid string"
Valid arguments are:
ping-host
ping-interval
ping-no-of-packets
Possible value(s) are enable or disable.
Command Syntax set ppp <interface> ping-keepalive ping-interval <5-65535>
Description
The time interval between subsequent ping attempts.
Maximum interval time is 65535 secs.
Default Value
30 secs
Success
OK
Error 1. Too few arguments
Too few arguments. Possible argument(s) are:
ping-host
ping-interval
ping-no-of-packets
Possible value(s) are enable or disable.
2. Invalid String
Invalid argument "invalid string"
Valid arguments are:
ping-host
ping-interval
ping-no-of-packets
Possible value(s) are enable or disable.
Command Syntax set ppp <interface> ping-keepalive ping-host <hostname/ip-address>
Description
Sets the server hostname to ping.
Default Value
NULL
Success
OK
Error 1. Too few arguments
Too few arguments. Possible argument(s) are:
ping-host
ping-interval
ping-no-of-packets
Possible value(s) are enable or disable
2. Invalid String
Invalid argument "invalid string"
Valid arguments are:
ping-host
ping-interval
ping-no-of-packets
Possible value(s) are enable or disable.