Set the Data bits for the serial port s0 to be taken for a Dialout session.
# set serial s0 data-bits <7/8>
Set the Stop bits for the serial port s0 to be taken for a Dialout session.
# set serial s0 stop-bits <1/1.5/2>
Set the Flow control for the serial port s1 to be taken for a PPP session
# set serial s1 flow-control <rts-cts/none>
Set the Parity for the serial port s1 to be taken for a PPP session
# set serial s1 parity <even/odd/none>
Set the Data bits for the serial port s1 to be taken for a PPP session
# set serial s1 data-bits <7/8>
Set the Stop bits for the serial port s1 to be taken for a PPP session
# set serial s1 stop-bits <1/1.5/2>
UDP Auto-Dialout Optional Configuration Settings
The following details are optional configurations:
Enable/Disable the Terminating Dialout Session using Terminate string
# set ip udp udp-terminate-monitor <enable/disable>
Set the Terminate-Monitor-String to Terminate the Dialout Session.
# set ip udp udp-terminate-string "+++inet"
Enable/Disable the Terminating Dialout Session using Inactivity Timeout
# set ip udp udp-inactivity <enable/disable>
Set the Inactivity Timeout to Terminate the Dialout Session.
# set ip udp udp-inactivity-timeout 300
Set the Baud rate for the serial port s0 to be taken for a Dialout session.
# set serial s0 baud-rate <Baud-rate>
Set the Flow control for the serial port s0 to be taken for a Dialout session.
# set serial s0 flow-control <rts-cts/none>
Set the Parity for the serial port s0 to be taken for a Dialout session.
# set serial s0 parity <even/odd/none>
Set the Data bits for the serial port s0 to be taken for a Dialout session.
# set serial s0 data-bits <7/8>
Set the Stop bits for the serial port s0 to be taken for a Dialout session.
# set serial s0 stop-bits <1/1.5/2>
Set the Flow control for the serial port s1 to be taken for a PPP session
# set serial s1 flow-control <rts-cts/none>
Set the Parity for the serial port s1 to be taken for a PPP session
# set serial s1 parity <even/odd/none>
Set the Data bits for the serial port s1 to be taken for a PPP session
# set serial s1 data-bits <7/8>
Set the Stop bits for the serial port s1 to be taken for a PPP session
# set serial s1 stop-bits <1/1.5/2>